of adults have periodontal disease
of implants affected by peri-implantitis
of biofilm invisible to white light
better outcomes with guided debridement
The Problem
You Can't Treat
What You Can't See.
For decades, periodontal and implant maintenance has relied on blind faith — the tactile sense of a probe. Biofilm, the primary driver of disease, is completely transparent to every white-light instrument on the market. Clinicians have been operating in the dark.


The same implant surface — under 405nm BioUView illumination (left) vs. 365nm Structure Mode (right)
The Solution
The "See · Treat · See" Workflow
BioUView establishes a definitive visual endpoint for every periodontal and implant maintenance procedure.
365nm · Structure Mode
Map the Terrain
Activate 365nm UV-A illumination. Healthy enamel fluoresces bright blue-white. Calculus and defective margins appear as dark shadows. You now have a complete map of what needs to be removed.
Treatment
Treat with Precision
Guide your laser, ultrasonic, or air polishing instrument with visual certainty. No more guessing. No more over-treatment. Remove exactly what the scope shows you.
405nm · Biofilm Mode
Verify & Document
Switch to 405nm violet illumination. Pathogenic porphyrin-producing biofilm glows red-orange. When the red is gone, the job is done. Capture the before/after for the patient record.
Competitive Advantage
In a Category of One.
No competitor offers any two of these three capabilities together — let alone all three in a single 3.9mm probe.
| Capability | BioUView | PerioView | QLF / DIAGNOdent | Industrial Scopes |
|---|---|---|---|---|
360° Articulation Sees around every corner | ✓ | ✗ | — | ✗ |
Dual-View (Front + Side) No blind spots | ✓ | ✗ | — | ✗ |
Subgingival Access Reaches where disease lives | ✓ | ✓ | ✗ | ✓ |
405nm Biofilm Detection Pathogenic biofilm glows red | ✓ | ✗ | ✓ | ✗ |
365nm Structure Mode Calculus mapping | ✓ | ✗ | ✗ | ✗ |
Medical-Grade Validated Clinical evidence base | ✓ | ✓ | ✓ | ✗ |
NDT Platform Architecture Industrial precision, clinical use | ✓ | ✗ | ✗ | ✓ |
Clinical Evidence
Better Outcomes.
Unshakable Trust.
Fluorescence-guided debridement is supported by a growing body of peer-reviewed evidence. When patients see the glowing biofilm on the screen, case acceptance approaches 100%. When clinicians can verify complete removal, outcomes improve dramatically.
Better clinical outcomes vs. blind SRP
Case acceptance when patients see biofilm
Porphyrin excitation — validated in PMC literature
Calculus contrast — UV-A autofluorescence

"When they see the glowing biofilm on the screen, they understand the need for treatment. Compliance is nearly 100%."
— KOL Periodontist, Early Access Program
Clinical Applications
One Platform.
Every Indication.
Peri-Implantitis
Direct 360° visualization of implant threads. Fluorescence-guided debridement until all red-orange biofilm is eliminated.
Periodontics
See subgingival calculus and biofilm in deep pockets. Establish a visual endpoint for scaling and root planing.
Caries Detection
Side-view camera maps interproximal lesions without tooth separation. Precise diagnosis for minimally invasive treatment.
Endodontics
Articulating side-view reveals missed canals, ledges, and isthmuses inside the root canal system.
Get Started
Ready to Stop
Working Blind?
Schedule a live, 15-minute virtual demo and see Fluorescence-Guided Dentistry for yourself.